- Contact Person : Ms. Zhou Tara
- Company Name : Shanghai Jevol Vehicle Inspecting Tech. Co., Ltd.
- Tel : 86-21-59101126
- Fax : 86-21-59101127
- Address : Shanghai,Shanghai,No.171 Pengfeng Road, Jiading District, Shanghai
- Country/Region : China
- Zip : 201802
Gas Tester (ET-550-5)
Detailed Product Description
Main technical parameters
1) Working environment
Temperature: 0 ∼40
Relative humidity: ≤85%
Atmospheric pressure: 86.0kPa∼106.0kPa
2) Voltage supply: AC220V ±22V,50 Hz±1Hz
3) Measuring Range and Resolution
Item | CO | CO2 | HC | O2 | NO |
Measuring Range | 0.00∼16.00 (×10-2) | 0.00∼18.00 (×10-2) | 0∼9999 (×10-6) | 0∼25.00 (×10-2) | 0∼5000 (×10-6) |
Resolution ratio | 0.01 (×10-2) | 0.1 (×10-2) | 1 (×10-6) | 0.02 (×10-2) | 1 (×10-6) |
4) Indication error
Gas type | Measuring Range | Indication error | |
Absolute error | Relative error | ||
HC | (0∼2000)×10-6 | ±12×10-6 | ±5% |
(2001∼9999)×10-6 |
| ±10% | |
CO | (0.00∼10.00)×10-2 | ±0.06×10-2 | ±5% |
(10.01∼16.00)×10-2 |
| ±10% | |
CO2 | (0.0∼18.0)×10-2 | ±0.5×10-2 | ±5% |
NO | (0∼4000)×10-6 | ±25×10-6 | ±4% |
(4001∼5000)×10-6 |
| ±8% | |
02 | (0.0∼25.0)×10-2 | ±0.1×10-2 | ±5% |
RemarkIt is acceptable if either of absolute error or relative error listed on the table is reached. |
5) Requirement
Response time: ≤10s, NO≤15s, O2≤12s
Preheating time: 15 min
Product characteristics
1) Measure concentration of HC, CO, CO2, O2, and NO in automotive exhaust emissions.
2) Large LCD screen
3) Automatic zero reset, high level of automation.
4) Imported core and sensor.
5) Automatically calculate and show Air Fuel Ratio λ
6) Equipped with rotation speed and oil temperature measure ports
7) With functions of License Plate Number entry and time display.
8) 500 groups of data storage and review, and functions of License Plate Number search.
9) RS-232 serial communication interface make the networking more convenient, and update the software.
10) Optional printer is available and you can print measure data directly.
11) Small size, light and easy to carry.